Naar de FAQ

HK 225M4 B35 4-6 IE3

E-MOTOR 400/690V 45,0KW 1475U B35 IE3
Product details for

HK 225M4 B35 4-6 IE3

P 50 Hz
45 kW
n 50 Hz
1,480 r/min
P 60 Hz
52 kW
n 60 Hz
1,780 r/min
LF 50 Hz
0.86
Factor IA / IN
7.9
η %
94
A
356 mm
B
780 mm
C
548 mm
H
225 mm
I 50 Hz
80.9 A
Ø D shaft
60 mm
Ø E
350 mm
Ø F
450 mm
All characteristics

Characteristics

Beschermingsklasse
  • IP 55 
Omgevingstemperatuur
  • -20 °C tot +40 °C 
Materiaal
  • Behuizing: aluminium 
  • Behuizing: grijs gietijzer (vanaf HK160...) 
Uitvoering
  • Ontwerp B3 / B5 
  • Voet demonteerbaar 
  • Vaste voet (vanaf HK 160M4...) 

Productbeschrijving

Notes
Caution! Measurement »B« can depending on design slightly vary in length.
Description
Self-cooling squirrel-cage energy-saving motors.
High Efficiency IE3 or Super Premium Efficiency IE4 according to (EG) 2019/1781.
Rated voltage 400/690 V 50 Hz, 460 V 60 Hz.
4-pin.
Voltage tolerance ±5 %.
All motors including thermal protection (PTC thermistor).

Product variants

17 Results
Show dimensional drawing
Identifier
P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
P 50 Hz = nominal output at 400 V/50 Hz
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
Factor IA / IN = start-up current IA / Nominal current IN
η = efficiency in % (at full load)

Shows 10 of 17

Column selection

P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
LF 50 Hz
Factor IA / IN
η %
A (mm)
B (mm)
C (mm)
H (mm)
I 50 Hz (A)
Ø D shaft (mm)
Ø E (mm)
Ø F (mm)
P 50 Hz = nominal output at 400 V/50 Hz
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
Factor IA / IN = start-up current IA / Nominal current IN
η = efficiency in % (at full load)