PR 30-4 V2

Hydraulic tube 30x4 1.4541

Hydraulic tube 30x4 1.4541

Produktdetails zu

PR 30-4 V2

Ø d1
30 mm
S
4 mm
Specific load I
371 bar
Specific load III
267 bar
Ø d2
22 mm
AD tolerance +/-
0.08 mm
ID tolerance +/-
0.15 mm
Alle Eigenschaften

Eigenschaften

Construction type
  • precision steel tube, seamless, (cold-drawn), metric 
Construction type addition
  • CFA = bright annealed (annealed; metallically bright) 
Design
  • metric 
Material
  • stainless steel X6CrNiTi18-10 (1.4541) 
Standard
  • DIN EN 10216-5 
Tube length
  • 5 to 7 metres*. 
Customs tariff number
  • 73044100 
Alle Eigenschaften

Productbeschrijving

Hinweise
The pressure figures are based on straight tubes.
The appropriate wall thickness needs to be calculated for tubes with bends as stipulated in DIN EN 13480-4.
*Stainless steel tubes are supplied in manufactured lengths according to EN 10216-5. In terms of production, these are usually 6 meters (+/- 1m). Order quantities are rounded to the nearest possible total length, without cutting.
Beschreibung
The stainless steel pipes made of materials 1.4301 (V1), 1.4541 (V2) and 1.4571 (V4) are supplied in CFA condition (bright annealed) as standard. This condition offers very good bendability and is the established standard in the hydraulics sector, particularly for the installation of pipelines.
Zusatzinformationen
Calculation analog DIN 2413
Specific load I: static (up to 120 °C)
Load case III: dynamic (up to 120 °C) stress range = P bar
Strength parameter: K 222 [N/mm²]
Safety coefficient: S 1.5
Fatigue strength: σSch/D 225 [N/mm²]
Tolerances: DIN EN 10305-1 (diameter-/wall thickness indication)
Elastic strength to DIN DIN 10216-5 Rp 1.0 to 50°C
The fatigue strength value was reduced in relation to the strength parameter by 1.4571.
Bestellhinweis
Other delivery conditions, such as CFD, are available on request and must be specified separately.

Produktvarianten

69 Ergebnisse
Maßzeichnung anzeigen
Bezeichnung
Ø d1 (mm)
S (mm)
Specific load I (bar)
Specific load III (bar)

Zeigt 10 von 69 an

Spaltenauswahl

Ø d1 (mm)
S (mm)
Specific load I (bar)
Specific load III (bar)
Ø d2 (mm)
AD tolerance +/- (mm)
ID tolerance +/- (mm)