K- 07 15 02 24

5/2-way pilot valve
DN
15 
Connecting thread
G 1/2″ -14 
Voltage
230 V AC, 50 Hz 
Download PDF
Enregistrez-vous maintenant pour accéder à notre boutique en ligne. 

Register now and access our complete product range and many exclusive services.

Product details for

K- 07 15 02 24

DN
15
Connecting thread
G 1/2″ -14
Voltage
230 V AC, 50 Hz
Circuit diagram number
35
Control
monostable
All characteristics

Characteristics

Function
  • 5/2-way 
Min. working pressure
  • 2,5 bar 
Flow rate 6 bar and 10 bar
  • 1500 Nl/min (G 1/4), 4600 Nl/min (G 1/2) 
Electrical connection
  • Coupler plug PG 9 - form B 
Protection IP
  • IP 65 (DIN 46244) 
Piston gate valve
  • stainless steel 
Seal
  • NBR 
Housing
  • aluminium anodised, blue 
Max. working pressure
  • 2.5 - 10 bar; Max. vacuum 10 bar (external pilot air) 
Temp. range
  • -10 °C to +60 °C 
Customs tariff number
  • 84818079 
All characteristics

Description du produit

Notes
Further information on request.
Description
This valve design, featuring the Tapered Tee Seal®, offers the ability to run without lubrication and supports almost any compressed air quality. The valves are largely resistant to dirt and can thus also be used under extreme conditions without any problems. Leakage is now a thing of the past and the spool no longer sticks, even after long idle periods.

Product variants

4 Results
Show dimensional drawing
Identifier
DN
Connecting thread
Voltage
Circuit diagram number
15 
G 1/2″ -14 
230 V AC, 50 Hz 
35 
DN = nominal diameter, nominal width

Column selection

DN
Connecting thread
Voltage
Circuit diagram number
Control
DN = nominal diameter, nominal width